Determinazione del recettore solubile della transferrina: valutazione di un metodo immunoturbidimetrico applicato all'analizzatore automatico mega
*Francesco Pepe, Giovanna Patrucco, Dario Cerrato
Biochimica Clinica: 2001; 25(5): 379-381 [Article in italian]
ABSTRACT. We have evaluated an immunoturbidimetric method for the measurement of serum transferrin receptor applied to the automatic analyzer MEGA. 86 serum samples, including a wide interval of normal and pathologic values, have been used for such an evaluation. Good analytic characteristics have been obeserved, concerning linearity, imprecision and calibration stability. The comparison with an ELISA method pointed out at acceptably good correlation, even if a significant underestimation was shown, not completely corrected by the use of method-specific reference values particularly as far as low values are concerned.
La valutazione di un esame diagnostico mediante curve ROC: alcune osservazioni
Marco B.L. Rocchi
Biochimica Clinica: 2001; 25(5): 382-389 [Article in italian]
ABSTRACT. In this paper the steps of the procedure of ROC curves drawing are analyzed; moreover, some remarks about methodological and statistical aspects are presented.
Valutazione multicentrica di un sistema analitico modulare: risultati della parte italiana
*Stefano Dolcini, Lorenzo Prencipe, Sergio Brenna, Alessandro Marocchi
Biochimica Clinica: 2001; 25(5): 390-394 [Article in italian]
ABSTRACT. This study reports the results of multi-center evaluation of the analytical system for clinical chemistry manufactured by Roche Diagnostics. The data reported are those concerning the italian contribution to the evaluation. Aim of this research was the field evaluation of the analytic performance, the software, and the reliability of the system. The evaluation was carried out in various European and American countries. Our laboratory was chosen for Italy. The configuration of our analytical system included the I.S.E. module and two photometric modules: D (Hitachi type 747) and P (Hitachi type 917). The instrument underwent series precision tests, repeatability tests on duplicate analysis series, comparative testing using two clinical chemistry analyzers, simulations of entire routines to compare the results with the lab's benchmark equipment, and error generation to gauge the instrument's reaction to a variety of situations. Overall, the entire multi-center evaluation took into consideration 84 analytes for a total of 720,000 results, 26,800 of which were obtained in our center. The CVs found for series imprecision were less the 2% for enzymes, substrates and electrolytes, and less than 4% per proteins and drugs. The CVs for imprecision between series were less than 4% and 5%, respectively.
Torna al Numero 04/2001 | Vai all'Indice di Biochimica Clinica | Vai al Numero 06/2001
Per chi desidera pubblicare su BC, sono disponibili le Istruzioni per gli Autori |
|
H O M E P A G E | C O N V E G N I | E D I T O R I A I N T ER N E T | S E R V I Z I |
Per osservazioni e commenti sui servizi WWW contattare bm@biomedia.net
per problemi tecnici mandate un mail a biomedialab@biomedia.net
1997, BIOMEDIA srl, tutti i diritti riservati
The material on this site may not be reproduced or otherwise
used without the prior permission of BIOMEDIA.